Determining wind and snow loads for solar panels 2 u s.
Asce 7 10 solar panels.
Model building codes have used asce 7 05 as the basis for several years which largely follows the design principles of allowable stress design.
Historic progression of wind calculations for solar 7khuh duh qr vrodu vshflilf surylvlrqv lq 6 ru lq.
Required 10 inch minimum distance from roof edge or ridge height above roof between 2 inches and 10 inches minimum gap of 0 25 inch between adjacent rows of panels in earlier version of ac 428 minimum gap was 0 75 inch.
The provisions contained within asce 7 10 for determining the wind loads on rooftop equipment on buildings is limited to buildings with a mean roof height h 60 feet.
In asce 7 16 there are two sections that cover rooftop solar panels.
Cain p e consultant.
The spreadsheet is in imperial units.
Asce 7 16 new parallel to roof method 7khvh uhvxowv irup wkh edvlv iru wkh qhz ioxvk prxqw phwkrg.
This paper will show how to calculate for wind and snow loads using both design principles.
For example asce 7 16 now clearly states that the weight of solar panels and their support are to be considered as dead loads 1 roof live loads need not be applied to areas covered by solar panels under a certain spacing or height 2 and seismic design is based on already established principles in section 13 3 for non structural component.
Asce 7 10 seaoc solar panel program calculator.
Wind loads on rooftop photovoltaic panel systems installed parallel to roof planes joseph h.
Drawing from published case studies and their own extensive experience with solar panels o rourke and isyumov present recommendations that are compatible with snow load procedures in minimum design loads and associated criteria for buildings and other structures including the asce 7 load factors thermal slope and exposure and asce 7 load.
Until all state building codes have transitioned to asce 7 10.
With the introduction of the asce 7 10 there are two potential design principles used for calculating wind and snow loads for pv systems in the u s.
This limitation was removed in asce 7 16 and thus the provisions apply to rooftop equipment on buildings of all heights.
Asce 7 16 v2017 wind load calculators updated for instant download.
All calculators updated per latest asce guidelines.
Section 29 4 3 addresses buildings of all heights with a flat roof or gable hip roofs with a slight slope less than 7 degrees.
Asce 7 10 with icc es ac 428 criteria physical constraints of ac 428 wind method.