Ventilation of attic spaces is required by most building codes as well as by roofing material manufacturers and the national roofing contractors association nrca.
Attic aiir vent neede.
While most are wired into your home electrical system solar powered vent fans are available that require no electrical hookup.
Attic ventilation works to protect the indoor structure of buildings in many ways such as maintaining a cold roof temperature to control ice dams to vent moisture that moves from the conditioned space to the attic to vent and expel solar heated hot air from the attic to lessen building cooling etc.
Choose one of the following products to meet the recommended intake nfva of 528 square inches.
Proper attic ventilation consists of a balance between air intake at your eaves soffits or fascias and air exhaust at or near your roof ridge.
Then aim for about 1 sq.
How many vents do you need.
It should be noted that these vents which expel warm moist air from the bathroom and food prep areas of the home need their own ducts and vent hoods which direct air to the home s exterior.
Ideally there should also be plenty of soffit intake space their calculations recommend 336 net square inches of open soffit ventilation to supply 700 cfm.
Most building codes require a ratio of 1 150 ventilation space to attic floor space.
That said air resistance and interference such as vent grates reduces the area of true ventilation.
Attic ventilation works on the principle that heated air naturally rises primarily utilizing two types of vents.
Before we explore how to ventilate an attic space it is prudent to understand how much ventilation is needed.
In other words the entire vent opening doesn t count as vented space.
According to the home ventilating institute hvi powered attic ventilators need to move a minimum of 700 cubic feet per minute cfm for 1 000 sq.
Attic for example has an area of 1 200 sq.
Federal housing authority recommends a minimum of at least 1 square foot of attic ventilation evenly split between intake and exhaust for every 300 square feet of attic floor space.
The following product options will allow you to achieve an intake nfva of 528 square inches.
Generally speaking you need a ratio of 1 300 where for every 300 square feet of ceiling space you need 1 square foot of attic ventilation.
First determine your attic area by multiplying the length by the width.
Ventsure inflow intake vent.
A 30 x 40 ft.
Allows cool dry air to enter the attic.
In of vent opening per 150 sq.
These vents and ducts should never share space with the roof vent and air should never be vented directly into the attic.
Ft of attic space for example 20 x 50 to be effective.
Intake vents located at the lowest part of the roof under the eaves allow cool.