It was new when the ac was put in 7 years ago.
Attic duct boot pictures.
Peel off part of the backing.
Pictures of the roof vents turbine vents.
They did a good job and the charge was reasonable.
They helped us replace air ducts and boots on the attic install a new furnace flue pipe bubble wrap the furnace plenum box seal all joints well.
Secure the fiberglass insulation in place around the boot with foil faced duct tape.
Today i bring you a few photos that are signs of a bad duct installation.
This way there is no infiltration at this point.
The next most typical type of duct systems is made of flexible duct.
The foam does have an advantage in that while the boots are being foamed one can also seal the joint between the boot and where the boot is mounted ceiling wall floor.
Air sealing all the ducts and air handler connections and seams and air sealing all the duct boots to the ceiling gypsum and any other penetrations is a critical first step prior to adding any insulation.
A homeowner in atlanta was getting a home energy upgrade and one part of it was getting a.
The attic ductwork is flex duct work.
Btw they offer 5 year warranty on their work.
Afterward i wrote about something i saw on his new home construction site that was a sign of a good duct installer.
Here s bob s trick for taping a seam on a pipe that s installed close to the subfloor.
I ve searched the forum and it looks like i do not have insulated boots and when i went up to the attic today i noticed the boot was cold to the touch and had a small draft coming from where the boot meets the sheetrock of the ceiling.
Either duct wrap the boots or foam them.
When the hot humid attic air contacts the cold duct or the cold duct boot the moisture in the air condenses on the cold surface just like the condensation that happens on a cold can of beer.
Last month while i was in austin homebuilder extraordinaire matt risinger gave me a tour of some of his projects.
Flexible duct is a plastic tube that is reinforced with wire and then insulated on the outside.
Slide the backing up and over the pipe.
Also they are detail oriented the clean up and rodent proofing work were completed with care.
Cut a piece of foil tape to length.
Flex ducts themselves do not sweat however if the.
The air in your vented attic is hot and humid just like all outdoor air in florida.
The really bad news is that with old metal duct systems the only option is replacement of the ducts to stop the rain in the attic.
If the ducts are going to be concealed all seams need to be taped or caulked.
I will use a combination of doors and windows great stuff and the normal expanding great stuff.
There are two main ways to solve this problem.
The point about testing expansion is a good point to consider.
4 if your round air ducts run below the joists lay one insulation batt on top of the duct.