Baby changing tables shall comply with sections 11b 309 and 11b 902 baby changing tables when deployed shall not obstruct the required width of an accessible route except as allowed by section 11b 307 2 baby changing tables shall not be located in toilet compartments complying with section 11b 604 8 within a multiple accommodation toilet facility.
Baby changing station height required by code.
California code considers baby changing tables as a work surface and requires clear floor space knee space and toe clearance and specified height requirements.
Ada regulations also state that baby changing stations must be located in an area that is easily accessible and free from obstructions.
For horizontal changing stations the ada requires that the unit protrude no more than 4 from the wall and be no higher than 27 inches from the floor.
The recent code amendment provides an exception to section 11b 603 5 which changes the reach height of operable parts at restroom accessories from 40 inches maximum to 48 inches maximum for baby changing tables.
Baby changing tables when deployed shall not obstruct the required width of an accessible route except as allowed by section 11b 307 2.
Authority has been left with each state and local government to adopt and enforce its own building codes but the office of the u s.
Facilities that are newly constructed or altered on or after march 15 2012 must comply with the 2010 ada standards.
Protruding objects units are not to protrude more than 4 inches from the wall when closed.
This is required so patrons using wheelchairs can easily access the unit as well as open and close the changing station.
Where a clear floor or ground space allows a parallel approach to an element and the side reach is unobstructed the high side reach shall be 48 inches 1220 mm maximum and the low side reach shall be 15 inches 380 mm minimum above the finish floor or ground.
Here is what the codes say.
Baby changing tables shall comply with sections 11b 309 and 11b 902.
When the unit s bed is opened and laid flat it must provide adequate knee clearance below the station.
See figure s 308 3 a below.
Ebruary baby changing stations and accessibilitycontinued35 type see figures 1 and 2.
Install at the perfect height.
11b 226 dining surfaces and work surfaces.
Knee clearance must extend 25 inches under a changing table and the unit must be 9 inches above the finish of the ground.
The ada mandates that baby changing stations be present in both men s and women s restrooms and must be placed at a height of 27 inches from the floor.
Assistant attorney general for civil rights has.